Old 06-10-2007, 10:36 PM   #1
trucky9754
Junior Member
 
Join Date: Jun 2007
Posts: 2
View trucky9754's Photo Album My Photos

Old Gallery
Default Dust Collection Unit

I just got a used industrial dust collection unit from a factory my son is working at. This unit is an Ace-ITT Holub Industry unit. The unit has a 1hp motor on it and it sits on top of a 55gal drum. It has 2- 4" openings so I can take the vac system in two directions. I have never owned a dust collection system so I am new to this. I was going to run pvc pipe around my shop and place "T's" in the locations where my equpiment is located at in my shop. Then run flexible tubing to my equpiment. My question is do I need to ground this pvc pipe. Is pvc pipe going to work for the main line or should I spend the money on the pipe designed for a vac system. I've talked to several people and some say it has to be grounded and others say it doesn't. I need as much help on this subject as possible. Thanks in advance
Trucky9754
trucky9754 is offline   Reply With Quote
Join Contractor Talk

Join the #1 Woodworking Forum Today - It's Totally Free!

Do you love woodworking? Are you looking to connect with other woodworkers? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for woodworkers to meet online. No matter what your skill level you'll find that WoodworkingTalk.com is a great community to join. Best of all it's totally free!

Join WoodworkingTalk.com - Click Here JOIN FOR FREE

Also view our DIY Forum here

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. WoodworkingTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any woodworking or home improvement task!
Old 06-11-2007, 08:05 AM   #2
Big Dave
Senior Member
 
Big Dave's Avatar
 
Join Date: Sep 2006
Location: Southwest Mo.
Posts: 1,036
View Big Dave's Photo Album My Photos

Old Gallery
Send a message via Yahoo to Big Dave
Default

You will need to ground it. I get a heck of a shock from my shop vac when picking up dust and chips and a dust collector will be much worse.
__________________
Do one thing at a time, do it well, then move on.
www.bigdaveswoodworks.com
Big Dave is offline   Reply With Quote
Old 06-11-2007, 08:22 AM   #3
solidwoods
Senior Member
 
Join Date: Apr 2007
Location: N.Central TN
Posts: 122
View solidwoods's Photo Album My Photos

Old Gallery
Default

Dust collection pipe should be grounded.
pvc pipe makes great pipe, but as is it has no way to ground.
I've seen copper wire run in side, and screws screwed into the pipe connected with wire. Both work OK, but long slivers can get hung up and cause a chip jam.

If you try a grounding concept like above, I'd try not glueing the joints till I worked out the bugs.

If the pvc run is short, it won't generate much static electricity.
If the run does makes static elec. you'll be the first to know it.

Metal pipe does cost more yes, but its easy to ground, and once you have the pipe you'll always have it, it doesnt degrade. And no static shocks or chance of a dust explosion, so it's not a bad investment.

One thing to watch is , a 1 hp dust collector won't allow a very long run, or many short runs open at once, or much elevation change. So blast gates on the machines not in use will help.

Also plastic flex pipe is a killer of vac performance, so keep it to a min.

I don't think this applies to your type of collector but: Running the chips into an open container with out the bag will get you a little better performance. The filter causes resistance to air flow.
I use one of the stand up dust collector rings that has an upper and lower bag, I removed the bottom of the lower bag. It is set on top of a box trailer just outside the shop. The chips enter the ring and fall out the bottom of the bottom bag and into the trailer.
jim
solidwoods is offline   Reply With Quote
Old 06-11-2007, 09:34 PM   #4
jodiemeglio
Senior Member
 
jodiemeglio's Avatar
 
Join Date: Jan 2007
Location: Carlisle, Pa
Posts: 169
View jodiemeglio's Photo Album My Photos

Old Gallery
Default

I shocked the crap out of myself today in the shop. I'll be grounding my lines tomorrow for sure!
__________________
Tile/Finish work www.donnellymeglio.com
jodiemeglio is offline   Reply With Quote
Old 07-01-2007, 12:43 PM   #5
Gerry KIERNAN
Senior Member
 
Join Date: Apr 2007
Location: Powell River British Columbia, Canada
Posts: 1,749
View Gerry KIERNAN's Photo Album My Photos

Old Gallery
Default Dust collection unit

Hi

I am putting together a dust collection system, that I bought from Busy Bee. It has 21/2 inch clear PVC pipe, tees, elbows, couplings, etc. I was putting some thought into ways of grounding the system, without impeding the flow, and I think I have it figured out. The system joints are slip fit, so I probably won't be gluing them together. What I thought I would do is drill small holes in each tee, coupling, or elbow, to fit # 10 scews. I would then install pan head screws with the head inside the part, so that the threads and shank stick out. I figured I would secure nuts to the screw threads with loctite, and the reinstall the fittings into the system. I would then connect copper wire to the screws, using electrical crimp on end terminals, and secure them with non locking nuts and washers. With the heads of the pan head screws inside the fittings there should be minimal interference with the air and particle flow.
I am wondering if I should ground the flex hoses to the equipment also, or will grounding the piping be enough? Any thoughts on this?

Gerry
Gerry KIERNAN is offline   Reply With Quote
Old 07-01-2007, 01:16 PM   #6
daryl in nanoose
Senior Member
 
daryl in nanoose's Avatar
 
Join Date: Feb 2007
Location: Nanoose Bay Vancouver Island BC Canada
Posts: 486
View daryl in nanoose's Photo Album My Photos

Old Gallery
Default

The biggest thing a person can do to maximize there system is to reduce the amount of 90 degree turns. Instead of T's use a y and go from there. Use lots of blast gates to minimize the length runs and minimize the amount of flex pipe. Don't glue the PVC togeather, use acrlic latex caulk after the system is put togeather that way if you have to change anything you will not have the hastle of glued pipe.
__________________
www.geocities.com/edimprovement
daryl in nanoose is offline   Reply With Quote
Reply

« Previous Thread | Next Thread »
Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Display Modes
Linear Mode Linear Mode
Hybrid Mode Switch to Hybrid Mode
Threaded Mode Switch to Threaded Mode

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off

Similar Threads
Thread Thread Starter Forum Replies Last Post
Dust Collection. dbhost Power Tools & Machinery 2 11-04-2008 02:21 AM
Dust collection TS3660 General Woodworking Discussion 10 05-04-2008 09:31 AM
dust collection carver348 General Woodworking Discussion 1 03-22-2008 11:15 PM
Dust Collection gaviaimmer General Woodworking Discussion 10 01-08-2008 10:13 AM
Dust Collection raymondb Design & Plans 16 10-06-2007 10:47 PM

Top of Page | View New Posts

All times are GMT -4. The time now is 09:04 PM.

Contact Us - Woodworking Forum - Top

Powered by vBulletin® Version 3.7.4
Copyright ©2000 - 2009, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.2.0
Woodworking Talk © 2005 - 2009 The Building Network LLC
Our Network: Contractor Forum | DIY Forum | Painting Forum | Electrician Forum | Drywall Forum